Data Sheet

www.dimensionengineering.com/products/Sabertooth2x32
Program tabs
Now that the inputs are set up, a program is created for each output. For example, the M1 tab holds the
program that controls the M1 motor output. Each program starts with an initial value read either from
an input or from the output of another program. Each program can have up to four commands. Click on
the box below the initial input and a list of options appear. Each of these will modify the command going
to the output channel. The commands operate in succession, following the arrows. After the last
operation, the value is sent to the output.
The program shown would set up an R/C dual rate switch. The program starts with an R/C signal on the
S1 input. If the R/C A1 input is positive, then the output is reduced by 50%. If not, then the signal passes
through unmodified and directly controls the M1 output.