User Manual

Performance features
Output buffers
A bare accelerometer chip has an output impedance of 32k, which is unsuitable for obtaining reliable
measurements when connected to an analog to digital converter. On the DE-ACCM2G, a dual rail to rail
operational amplifier buffers the outputs from the LIS244ALH, greatly reducing output impedance.
Supply filtering
A pair of resistors and a 0.1uF ceramic bypass capacitor on the DE-ACCM2G2 provide excellent power
supply decoupling. No external capacitors are necessary between Vcc and GND.
Output filtering and noise
A pair of 10nF capacitors limit the noise figure of the DE-ACCM2G2, without overly sacrificing bandwidth.
RMS noise is typically 6.2mg, and output bandwidth is 500Hz - making it suitable for high frequency
sampling of acceleration.
Protection features
Reverse voltage
Even the best engineers sometimes get their wires crossed. In the event that you mix up VCC and GND, a P
channel MOSFET will prevent current from flowing – protecting the DE-ACCM2G2 from damage. This
protection is only designed to work with DC voltages. Do not apply AC voltages to the power pins.
Improper insertion
A resistor network ensures that the DE-ACCM2G2 will not be permanently damaged if you insert it
backwards (i.e. apply power to the output pins). The product will not function properly while it is used
backwards. Do not leave the DE-ACCM2G inserted backwards for more than 5 minutes at a time.
Output shorting
The operational amplifier driving the DE-ACCM2G2’s outputs is capable of handling a direct short from the X
and Y outputs to ground for as long as you want.