User Manual
Wire Sizing Guidelines
______________________________________________________________________________
Continuous Amp Draw
per motor
Motor Leads Min.
Wire Size
Battery Leads Min.
Wire Size
< 25A 12ga 10ga
25A < 45A 10ga 8ga
> 45A 8ga 6ga
> 60A 6ga+ 4ga+
Thermal Camera Photo
This thermal camera photo was taken with a Sabertooth 2x60 running 40A continuously on both
motors. The left side is using 12ga stranded wire. The right side is using 8ga stranded wire. As
you can see, the 12ga wire is not only heating itself up due to being undersized, but it is also
causing heat to build up in the connections around it.
It is important to use adequately sized wire. Using undersized wire will
create added stress in the form of heat for the entire system and could
cause a premature failure!