I NSTALLATI ONMANUAL Website:https://dimakai.com Service Contact: service@dimakai.
3、Accessory Drawing 1、New installations NOTE!!! 1.Supply lines should be purged to clean impurities before connecting the unit. 2.The hot water supply should be connected to the left and the cold water supply to the right, when viewed from the operating position. If this is not taken into account can cause permanent damage to the cartridge. 3.Screw connections and test for leaks. 4.Using a spirit level on the cams, the mixer align horizontally,vertically and parallel to the wall. 5.
4、Dimentional drawing 5、Chiseling wall diagram Unit:inch Unit:inch Shower head outlet Bath spout outlet Handle shower outlet Hot water inlet Cold water inlet For 3-Function outlets ≤3" 9" 1.8" 6" 2"-2.
6、Pipe-connection diagram 7、Water test and leak detection 1.After connecting all pipes, please dis-assembling the plastic protection cover ,and switch on/off the cartridge , check all connections without any leakage, and all connections connecting to the required functional outlets. 2.Re-install the plastic protection cover to the valve. Notice : the lines on thermostatic cartridge handle bar and gears must be at the same level.
8、Wall tiling program 1.Use a parallel ruler to make sure the wall and valve being parallel. 9、Cover and handle installation 1.Take off the plastic protection cover. 2.Put the cover board on the valve and tight the handle firmly. 2.Use a knife to cut the rest of plastic edge above the tiles. Tiles Wall Alignment Plastic edge above the tiles Notice : The lines on thermostatic cartridge handle bar and gears must be at the same level.
1 0、Shower sets installation 9/16 11、Handle shower installation 10/16
12、Temperature setting 13、Temperature Limitation The actual conditions, will have a significant impact on the temperature measured at the point of discharge. In the event that the safety stop at 100°F does not establish the precise temperature, follow the instructions below 1.The safety stop limits the temperature range of 100ºF, by pressing the button on the thermostatic handle, the temperature limit can be canceled and get a higher temperature. 14、Operation 1.
15、Thermostatic Cartridge 1.To ensure long-lasting functionality of this product, we recommend regular maintenance and care. 2.To get the thermostatic cartridge, inserted under pressure, loosen the screws on the underside of the body ,as shown in the image. 3. Impurities and lime must be cleaned with vinegar or softener, and lubricate the join with thermo-resistant grease or oils. 4.
18、Problems and Solutions 1. If there is no hot or cold water Checking the pipes or filters are not clogged, that the pressures are balanced and that the thermostatic cartridge has no impurities. 2. If the thermostatic mixer does not generate the temperature of 100ºF Check that the conditions are correct, as described in section 2.TECHNICAL DATA. Regulate again the thermostatic cartridge following the instructions in paragraph 5.TEMPERATURE SETTING. 3.