RF 100 Primer Filler, May 2007 5/22/07 9:35 AM Page 1 illon recision Products, Inc.
RF 100 Primer Filler, May 2007 5/22/07 9:35 AM Page 2 RF 100 Primer Filler Primer Filler Units & Large Primer Filler, Small Primer Filler, Large Conversion, Small Conversion, Conversions #97077 #97111 #17902 #17903
RF 100 Primer Filler, May 2007 5/22/07 9:35 AM General Information Page 3 Operation: Plug your primer filler into a 110 volt AC power supply/generator. The power is turned on by the red rocker switch on the cord. Your primer filler is shipped ready to fill either large or small primers. If you are going to load small primers or standard large, then your machine is ready to load, right out of the box. NOTE: Remington primers require the use of the ‘B’ stabilizer plate (#17295).
RF 100 Primer Filler, May 2007 5/22/07 9:35 AM Page 4 Changing Primer Sizes Fig. 5 Changing Adapters Using a 7/16” wrench, remove the four bolts (#17894) that hold the clear protective cover. Set the cover aside. Fig. 7 #17285 (large) #17286 (small) #13964 2. While pressing down on the plastic tray with your index finger, slide the cardboard jacket off. Fig #5 Fig.
RF 100 Primer Filler, May 2007 5/22/07 9:35 AM Page 5 Install the “B” stabilizer plate. Place one upside-down primer on the ramp in front of the stabilizer plate using an Allen wrench. Place the primer under the stabilizer plate – the primer should fall off of the ramp and fall to the bottom of the bowl. If the primer only falls partially out, you need to increase the distance between the stabilizer plate and the edge of the bowl. Tighten the stabilizer plate screw. Replace the clear protective cover.
RF 100 Primer Filler, May 2007 5/22/07 9:35 AM Troubleshooting continued… Page 6 testing after each adjustment. The feed adapter is designed to float. When allowed to move, the adapter absorbs some of the vibration. When the screw is too tight, all vibration transfers to the bowl causing it to become violent and throw primers out of the bowl. Problem: The machine ‘picks-up’ speed during operation, or vibrates so violently that primers are thrown out of the bowl.
RF 100 Primer Filler, May 2007 5/22/07 9:35 AM Page 7 Primer Filler Schematic 17894 (4) 17953 (4) 17293 LEXAN COVER 17294 (SMALL) 17295(LARGE) 13964 (3) 17903 (SMALL TUBE) 17902 (LARGE TUBE) 17285 (RED ADAPTOR) 17285 FEED ADAPTER, LARGE (red) (BLUE ADAPTOR) 17286 FEED 17286 ADAPTER, SMALL (blue) 14040 HI TCH PI NCLI P 17898 NYLON FLAT WASHER 7
RF 100 Primer Filler, May 2007 5/22/07 illon recision Products, Inc. Manufacturers of the World’s Finest Loading Equipment 9:35 AM Page 8 8009 E. Dillon’s Way Scottsdale, AZ 85260 (480) 948-8009 Fax: (480) 998-2786 For technical assistance or orders: (800) 223-4570 To place an order by stock numbers or to quickly check the status of an order only.