Pallet Jack Scale DWP-PJ DWP-PJ-P User Manual DWP-PJ
Specification 1. Model: DWP-4400PJ Pallet Jack Scale 2. Accuracy: Class Ⅲ, n=5000 3. Sample Rate: 10 times / second 4. Load cell sensitivity 1.5~3mV / V 5. Scale interval: 1/2/5/10/20/50 for option 6. Display: 6 bits LCD,6 state indicating signals 7. Power supply: Battery DC6V/4AH 8. Operating temperature/humidity: 0~40℃; ≤90%RH 9.
Installation a. Take out the handle from the package and put the release latch all the way down. Mount the handle onto the pallet jack. b. First take out the lock of the handle axis. c. Then slide the axis out so the handle can be inserted.
d. Insert the handle and slide in the axis. e. Place the axis lock back in. f. Put the chain through the whole on the axis and straight down.
g. Press the paddle and insert the end of the chain into the paddle slot. (You can adjust the screw at the end of the chain to adjust the tightness of the handle. h. Press down the handle and take out the safety lock.
Indicator 1 Introduction ·Simple operation ·Keyboard calibration and configuration ·Weighing up to 1:15,000 divisions ·Excitation voltage: DC 5V; Up to 4,350 Ω load cells can be used ·Manual or automatic memory accumulation facility ·High Resolution (×10) Display ·Selectable digital filtering ·Selectable automatic power off ·6-bit Display: 0.8 inches LED ·Selectable display resolution: 1/2/5/0.1/0.2/0.5/0.01/0.02/0.05/0.001/0.002/0.005/10/20/50/100/200/500/0.10/ 0.20/0.50/0.010/0.020/0.
【→】 Move the flashing digit to the right during configuration or setting Preset tare 【↑】 The display is temporarily set to high resolution increment the flashing digit during configuration or setting preset tare; 【→0←】Zero the display, set the zero point or enter a tare value 3 Display status 〖AC〗 〖→T←〗 Mains power is applied to the indicator A weight has been tare display is showing the net weight 〖 Battery capacity less than 30% 〗 〖→0←〗 〖-AUTO-〗 〖◣◢〗 lb 〖 〖- 0〗 0 .
4.4 Continuous ASCII RS-232 data output format 4.4.1 Automatic Output 4.4.1.1 Address: Adr = 00 The ASCII data format is “=,X1,X2, X3,X4,X5,X6” =,X1 , X2, X3 , X4, X5, X6 X1, X2, X3, X4, X5, X6 is weight data. If the weight is 〖 100.00〗kg, the continuous output is = 00.001 = 00.001= 4.4.1.2 Address: Adr = 99 The ASCII data format is “=,X6,X5,X4,X3,X2,X1” =,X6 , X5, X4 , X3, X2, X1 X6, X5, X4, X3, X2, X1 is weight data.. If the weight is 〖 100.00〗kg, the continuous output is = 100.
Press【↑】 〖002000〗 For example: F·S=3000 〖003000〗 5 6 Press【﹡】 Press【→】 Press【﹡】 Press【→】 Press【→】 Press【↑】 〖FLt 10〗 〖FLt 00〗 Sets digit Filter parameters :00-99 The display will updata faster and filter faster as The filter parameter is changed from 99-00 For example: FLt = 00 〖AUtP00〗 Sets Automatic Power Off function 〖AUtP00〗 AUtP=00 Not automatic power off 〖AUtP00〗 AUtP=01 Automatic power off th digit express the choice of zero trace range (1--9): 1:0.4 d 2:0.8 d 3:1.2 d 4:1.6 d 5:2d 6:2.
Pressed【﹡】key three times during calibration or configuration, The indicator will display. To view the A/D counts, press the 【→】key when 〖-A-d-〗is displayed press the【﹡】key to return to weighing mode. 8 Zero When the weight is stable, Press 【→0←】key for two seconds to set the zero point and zero the display. the 【→0←】status LED is turned on. 9 Tare 9.1 Digital tare press【→】key , set tare with【→】and【↑】key , then press【→0←】key , the input data is tare , Tare status LED is turned on. 9.
Press【﹡】 〖AUt 0〗 the selection of manual/automatic accumulation AUt = 0, manual accumulation AUt = 1, automatic accumulation and print when weight is added, 〖AUTO〗indicator is lit. AUt=2,automatic memorize displayed value when weight is added. Accumulate and print final stable values after load down to below 20d. 〖AUTO〗indicator is lit. AUt=3,dynamic weighing method. At weighing >20d: the buzzer sounds “du”and lock is displayed for 6 seconds. When a new data is fixed, lock is displayed again for 6 seconds.
completed 5 press【↑】 〖C 30〗 display sample’s quantity, 【↑】is change-over key between weight and quantity display (2) Counting operation: place the object on scale, weight is displayed, press【↑】, 〖C 255〗is displayed, and the display changes over to the quantity of the object. When the display is stable, press 【∴】, accumulate the weight and quantity. Accumulation can be done only at counting status.
kg or lb is selectable. The unit of weighing is kg normally. You can change it to lb by pressing and holding 【﹡】key 2 seconds at least. 17 Connection to Mini-printers Connect serial port printer Type Up-16TS as follows: Indicator Serial Port Printer 9 pin hole 25 pin needle 3 TXD 2 5 GND 7 Note: Before connection to printer, communication address is set as Adr=01; baud rate is set as b=2400. Print operation with serial port printer is as follows: 17.1.