11.5 Diesel Notching CV132 & 155
Sound CV155 customizes diesel engine notching and CV132 controls notching 
rate.
TABLE XIX: Diesel Notching CVs
CV# CV 
Value
Eect
CV155 00
default
Automatic notching 
Changes diesel RPM settings at 8 distinct throttle 
speeds controlled by CV132
CV155 01 Semi-automatic notching. 
F6 ON increases current notch setting.
F7 ON decreases current notch setting towards the 
lowest current throttle notch setting
CV155 02 Manual notching
F6 ON increases current notch
F7 ON decreases current notch 
without regard for current throttle setting which con-
trols just motor speed
CV132 127 
default
Notch Rate 0-255
11.6 Steam Chuff/Cam & Gear Rotation Trim CV133 & 134
The cam input is available for steam installations to synchronize chufng. 
CV133 controls the Steam Chuff/Cam conguration in the decoder. The range 
of values for this CV is 01-128. 
Enable an external cam by setting CV133 to the value of 128. Install a cam on 
the cam lead to provide feedback that will match chufng to the actual move-
ment of the locomotive. 
To get synchronized chufng without installing a cam, Set CV 133 to a value 
between 01 and 127. The factory default is 63. This lets you approximate the 
diameter of the driver from 1-127 inches to synchronize the chufng. You may 
need to experiment with this setting to get the best result. 
CV134 controls the gear rotation trim where a value of 32 equals a 100% ratio.