35
Expression Pedal Calibration
The Expression Pedal on the RP90 needs to be recalibrated for use after a factory reset has been
performed. This calibration procedure is automatically entered after a factory reset procedure.
(You can also initiate the calibration procedure by pressing and holding both Footswitches for
approximately 5 seconds.) In the event the Pedal’s calibration fails, or if the Pedal does not function
properly, it can be re-calibrated using the Pedal Calibration procedure. This will not erase the
User presets. The procedure for Calibrating the Expression Pedal is as follows:
Press and hold the Up/Down Footswitches until  appears in the display ( and 
will be displayed before  is shown). Release the Footswitches at this time.
When the Display prompts you with , rock the Expression Pedal forward (toe down)
and press either Footswitch.
When the Display prompts you with , rock the Expression Pedal back (heel down)
and press either Footswitch.
If calibration is successful,  will appear briefly in the Display and the RP90 will return
to Performance mode. If the calibration procedure fails,  will appear in the Display fol-
lowed by . Steps 2 and 3 should be repeated until calibration is successful.
Press and hold the Up/Down Footswitches until  and then  appears in the Display
( and  will be displayed before  is shown). Release the footswitches at this time.
1.
2.
3.
4.
5.