Installation Instructions
30Installation Guide
GB
• LNB Type: Press [Vol ] to switch
among “Standard”, “User” and “Univer-
sal” mode.
For Example: If you use a Dual LNB,
then you should select “User” option
in “LNB Type” and set the correct fre-
quency in LNB type.
• 22K: Use [Vol
] to switch “ON” and
“Off”. The 22KHz signal is used in KU
universal LNBs to change between low band and high band.
! Notice:
After choosing LNB type “Universal” you cannot modify 22K.
• DiSEqC1.0: Use [Vol ] to switch the options or press [OK] to open the DiS-
EqC1.0 option list to select directly with [CH ], press [OK] to confi rm it.
• DiSEqC1.1: Use [Vol ] to switch DiSEqC1.1 option or press [OK] to enter
DiSEqC1.1 option to select directly with [CH ], press [OK] to confi rm it. The op-
tions of this item are: Disable/CCard1 M1 Port1/CCard1 M1 Port2/
CCard1 M1 Port3/CCard1 M1 Port4/CCard1 M2 Port1/CCard1 M2 Port2/
CCard1 M2 Port3/CCard1 M2 Port4/CCard1 M3 Port1/CCard1 M3 Port2/
CCard1 M3 Port3/CCard1 M3 Port4/CCard2 Port1/CCard2 Port2/
CCard2 Port3/CCard2 Port4/CCard2 Port5/CCard2 Port6/CCard2 Port7/
CCard2 Port8/CCard2 Port9/CCard2 Port10/CCard2 Port11/
CCard2 Port12/CCard2 Port13/CCard2 Port14/CCard2 Port15/
CCard2 Port16.
• Positioner: Press [Vol ] to select between “Off/DiSEqC1.2/USALS”.
! Notice:
When you select “DiSEqC1.2 or USALS”, “DiSEqC1.0” and “DiSEqC1.1” items will be
disabled.
• Polarity: Press [Vol ] to switch between “Auto/H/V ”.
• Toneburst: Press [Vol ] to switch this function “On” or “Off”.
5. After you completed your modifi cation, on the “TP Scan” item, press [OK] twice to
start scanning.
4. INSTALLATION
BDA Imperial DB 2_basic_GB_MK.in30 30BDA Imperial DB 2_basic_GB_MK.in30 30 07.11.2008 13:30:05 Uhr07.11.2008 13:30:05 Uhr