Installation guide
Installing a DECarray Cabinet
4.4 Installing a DECarray Cabinet in a DSSI VAXcluster Configuration
c. Install one end of the 108-inch DSSI cable (PN BC21Q–09) to the I/O
panel on the system cabinet (Figure 4–9).
• Connect the DSSI cable from the DSSI port 1 (of the I/O panel) to
the first DSSI connector of the first KFMSA bulkhead connector on
the system I/O panel.
• Connect the DSSI cable from the DSSI port 2 (of the I/O panel) to
the second DSSI connector of the first KFMSA bulkhead connector
on the system I/O panel.
• Connect the DSSI cable from the DSSI port 3 (of the I/O panel) to
the first DSSI connector of the second KFMSA bulkhead connector
on the system I/O panel.
• Connect the DSSI cable from the DSSI port 4 (of the I/O panel)
to the second DSSI connector of the second KFMSA bulkhead
connector on the system I/O panel.
• Connect the DSSI cable from the DSSI port 5 (of the I/O panel) to
the first DSSI connector of the third KFMSA bulkhead connector on
the system I/O panel.
• Connect the DSSI cable from the DSSI port 6 (of the I/O panel) to
the second DSSI connector of the third KFMSA bulkhead connector
on the system I/O panel.
Note that DECarray I/O panel DSSI ports 7, 8, 15, and 16 are not used.
4–30 Installing a DECarray Cabinet