Installation guide

Installing a DECarray with a VAX 4000 System
D.2 DSSI VAXcluster Installation of a DECarray
D.2 DSSI VAXcluster Installation of a DECarray
As many as two pairs of DSSI VAXcluster configured VAX 4000 systems can be
used with a single DECarray.
A single DECarray requires connection to two DSSI adapters to support each
DSSI bus. The VAX 4000 Model 300 provides two embedded DSSI adapters on
the KA670 CPU module and also supports up to two KFQSA DSSI adapters
installed in the system Q-bus backplane. The VAX 4000 Model 200 provides
one embedded DSSI adapter on the KA660 CPU module and also supports up
to two KFQSA DSSI adapters installed in the system Q-bus backplane.
In a DSSI VAXcluster configuration, up to six ISEs and two adapters can be
supported on a single DSSI bus. That configuration can consist of one tape ISE
and up to five disk ISEs or six disk ISEs (where one disk ISE is in the system
enclosure). For further information on DSSI VAXcluster configurations, refer
to the customer hardware information kit.
A fully configured DSSI VAXcluster system could contain one of the following:
Two TF857 magazine tape ISEs. 16 RF disk ISEs (in SF7x storage
enclosures) and and two ISEs internal to the systems enclosure.
One TF857 magazine tape ISE. 16 RF disk ISEs (in SF7x storage
enclosures) and three ISEs internal to the systems enclosure.
16 RF disk ISEs (in SF7x storage enclosures) and four ISEs internal to the
systems enclosure.
Figure D–7 shows the possible DSSI VAXcluster buses.
D–16 Installing a DECarray with a VAX 4000 System