Installation guide

Installing a DECarray with a VAX 4000 System
D.1 Single-System Installation of a DECarray
Note
A single-system DSSI bus can only be connected from a VAX 4000
system to a single DECarray and then terminate in that DECarray. No
additional expanders can be connected to that DSSI bus.
For a VAX 4000 Model 200, DSSI bus 0 connect to ports 1 on the DECarray.
The first KFQSA adapter connects to port 2 and the second KFQSA adapter
connects to port 3.
For a VAX 4000 Model 300, DSSI bus 0 and 1 connect to ports 1 and 2 on the
DECarray. The first KFQSA adapter connects to port 3 and the second KFQSA
adapter connects to port 4.
This section describes the procedures for installing the DECarray in a
single-system configuration correctly and safely. Digital Services or trained
installation personnel must perform the procedures.
Ensure that all precautions for site preparation have been completed.
The following procedures describe how to:
Inspect the DECarray for proper configuration (Section D.1.1)
Cable the DECarray with an existing VAX 4000 system in the single-
system configuration (Section D.1.2)
Check the DECarray for correct operation (Section D.1.3)
D–4 Installing a DECarray with a VAX 4000 System