Installation guide
Converting a Single-System Configuration to a DSSI VAXcluster Configuration
C.2 Conversion Procedure
C.2.1 Split-Bus to Through-Bus Conversion
Use the following steps only if you are converting an SF7x storage enclosure
in position 3 or 8 of an DECarray from single-system to DSSI VAXcluster
configuration. SF7x storage enclosures in position 3 and 8 must be converted
to through-bus mode.
CAUTION
Maintain ESD precautions at all times. Before performing the following
steps, locate the ESD strap in the ESD pouch at the bottom of the front
door.
To maintain stability, extend only one SF7x storage enclosure or
magazine tape ISE on the slide mounts at a time.
1. Remove the OCP by firmly grasping the right and left side of the OCP and
pulling the OCP straight off.
2. Loosen the four captive slide assembly screws. At the rear, push the inner
assembly out until the drawer locks in the service position.
Note
Do NOT completely remove the SF7x inner drawer assembly from the
extrusion tube.
3. Reconfigure the TTM for through-bus mode by first moving the small black
jumper to the through-bus terminals. Then move the cable connector from
J3 to J5, and the cable connector from J2 to J4 (Figure C–2).
4. Push the SF7x inner assembly back into the extrusion tube. To prevent
pinching any cables, be sure that all cables are dressed correctly.
5. Tighten the four captive slide assembly screws.
6. Set the DSSI ID number switches behind the OCP front door of positions 3
and 8 to match those in positions 1, 2, 4, and 7 (Table C–1).
7. Replace the OCP by lining up the taps on the back of the OCP with the
slots on the front of the storage enclosure. Firmly press the right and left
side of the OCP.
C–6 Converting a Single-System Configuration to a DSSI VAXcluster Configuration