9.4 Bringing the RF Disk ISE On-Line
9.4 Bringing the RF Disk ISE On-Line
This section describes the procedure for bringing the ISEs in the storage
enclosure on-line.
1. Ensure that the DSSI node ID switches are set correctly, if applicable.
2. Place the ac power switch at the rear of the storage enclosure to the 1 (on)
position.
3. Press all drive dc power switches.
4. Press all Ready buttons on the OCP, one at a time.
5. If no Fault indicators are lit, then continue. If a Fault indicator is lit,
recycle the dc power once. If the failure appears again, refer to the
previous section.
6. Run the EVCXE or EVCXF programs to add the new disk ISE to the
configuration and to change any disk ISE internal parameters, if necessary.
7. Update the system configuration sheet.
8. Run DRVTST and DRVEXR (under DUP) to verify the correct operation of
the new disk ISEs.
9. Return the system to the user.