Installation guide

Installing the Magazine Tape ISE in a DECarray Cabinet
8.4 Labeling the DSSI Cables and Magazine Tape ISE
8.4 Labeling the DSSI Cables and Magazine Tape ISE
For a single-system configuration, use the following colored labels on the TF8x7
OCP door, magazine tape ISE front panel, and all DSSI cables.
Label Colors Connections
Blue Port 1, positions 5, 1, 3
Red Port 2, positions 6, 2, 3
Yellow Port 3, positions 4, 8
Green Port 4, positions 7, 8
For a DSSI VAXcluster configuration, use the following colored labels on the
TF8x7 OCP door, magazine tape ISE front panel, and all DSSI cables.
Label Colors Connections
Blue Port 1, positions 5 and 1, port 9
Red Port 2, positions 6 and 2, port 10
Yellow Port 3, position 3, port 11
Green Port 4, position 4, port 12
Blue with white stripe Port 5, position 7, port 13
Red with white stripe Port 6, position 8, port 14
8–36 Installing the Magazine Tape ISE in a DECarray Cabinet