Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.5 Installation Procedure
6. Check the DSSI ID switches on the OCP.
Open the door on the front of the OCP. Ensure that the DSSI ID switches
(the three rightmost switches) are set according to Figure 6–11. If they
are not, then use a pointed instrument to set the switches to their correct
configuration. Refer to Table 6–3.
Note
The leftmost switch (MSCP) should in the down or enabled position at
all times, unless you are instructed to change it to the up or disabled
position.
Table 6–3 DSSI ID Switch Settings (SF7x Only)
Positions 1, 2, 4, and 7
1
Left Rear (LR)
Left Front (LF)
Right Front (RF)
Right Rear (RR)
001
010
011
100
Positions 3 and 8 (single-system only)
1
Left Rear (LR)
Left Front (LF)
Right Front (RF)
Right Rear (RR)
101
110
110
101
1
The switch settings for OCPs in these positions are 0 = down and 1 = up.
6–24 Installing the SF7x Storage Enclosure in a DECarray Cabinet