Installation guide

Installing the SF3x Storage Enclosure in a DECarray Cabinet
5.5 Cabling the SF3x in the DECarray Cabinet
Figure 5–18 Cabling an SF3x in Through-Bus Mode
MA-0437-92.DG
P1
P2
P3
P4
Terminator
Terminator
5.5.1.3 Cabling Positions 2, 3, 4, 7, and 8
CAUTION
Before performing the following steps, refer to the system documenta-
tion for the correct procedure to perform an orderly shutdown of the
system that the DECarray is connected to.
1. At the rear of the DECarray, locate the DSSI I/O panel at the bottom. Use
a 3/16-inch flatblade screwdriver to loosen the two captive screws at the
right of the panel.
2. Swing open and remove the panel from the cabinet frame.
CAUTION
Use care not to disturb or damage power cords and DSSI cables that
are already connected to the DSSI I/O panel.
3. Remove the two Phillips screws that hold the panel blank in the
appropriate ports of the I/O panel. Refer to Section A.4 to identify the
appropriate I/O ports for your installation.
5–34 Installing the SF3x Storage Enclosure in a DECarray Cabinet