Installation guide

Installing the SF3x Storage Enclosure in a DECarray Cabinet
5.4 Installation Procedure
5. Make sure the DSSI node ID assignments are correct. The DSSI node
ID for each slot in the SF3x backplane comes factory set, as shown in
Table 5–3. However, some configurations may require you to change the
DSSI node ID to something other than the factory setting.
Table 5–3 SF3x Factory-Set DSSI Node IDs
Position Backplane Location DSSI Node ID
A upper left slot 0
B upper right slot 1
C middle left slot 2
D middle right slot 3
E lower left slot 4
F lower right slot 5
You can change the DSSI node ID for an ISE in any given slot position by
using DIP switches provided on the SF3x enclosure’s transition module.
Figure 5–12 shows the location of the switches for each slot position.
Table 5–4 shows what the switches must be set to for each slot position.
5–22 Installing the SF3x Storage Enclosure in a DECarray Cabinet