Installation guide
7–2 Installation Troubleshooting
7.1 Troubleshooting the SF72 Storage Enclosure
This section presents symptoms of a failed device, the probable cause or
causes of the failure, and the corrective action to take for correcting the
failure. Much of the corrective action calls either for taking a device or
devices off-line or for removing power from the enclosure containing the
failed device.
WARNING
Take all ESD and safety precautions when handling the devices,
more specifically, when taking a device off-line or when removing
a device. Failure to do so will damage the device.
Use the following basic steps for all troubleshooting that you perform for
the RF72 disk ISE in an SF72 storage enclosure, as it resides in an SF200
storage array:
1. Inspect the ISE’s operator control panel (OCP). Is a Fault indicator
lit? If so, press the Fault button and read the error code.
2. Access the ISE in question. Open the front or rear of the SF72
enclosure and gain access to the ISE’s various cables and check that
they are seated correctly.
3. Run various tests on the ISE by using DUP.
4. According to the findings from the error codes and results from DUP,
repair or replace the ISE.
5. Run EVCXE configuration programs, EVCXF configuration programs,
or both.
6. Verify the repair or replacement of the ISE with DRVTST and
DRVEXR under DUP.
7. Return the system to the user.