Installation guide

Installing the SF72 Storage Enclosure in an SF200 Storage Array 5–69
NOTE
The following step assumes that no SF72 storage enclosures
are installed internally in the system cabinet. If there are SF72
storage enclosures installed in the system cabinet, then one
of the KFMSA modules installed in the system XMI backplane
must be connected to those SF72 storage enclosures. DO NOT
USE this KFMSA module or its DSSI connections to connect
the system to the SF200 storage array.
10. Plug the other end of the 108-inch DSSI cables into the appropriate
ports on the VAX 6000 system I/O panel at the rear of the system
cabinet. To determine which of the two DSSI connectors on the
system I/O panel to connect to:
a. Locate the DSSI connectors on the system I/O panel labeled
BLUE/WHITE and RED/WHITE.
b. From port 5 on the SF200 I/O panel, connect the 108-inch DSSI
cable to the right DSSI connector (BLUE/WHITE) of the first
system I/O panel.
c. From port 13 on the SF200 I/O panel connect, the 108-inch DSSI
cable to the right DSSI connector (BLUE/WHITE) of the second
system I/O panel.
CAUTION
Do not apply power to the SF72 enclosure at this time.