Installation guide

5–56 Installing the SF72 Storage Enclosure in an SF200 Storage Array
5.2.2.3 Cabling Position 2
WARNING
Before performing the following steps, refer to the system
documentation for the correct steps to perform an orderly
shutdown of the system that the storage array is connected to.
The SF72 storage enclosure installed in position 2 of the storage array has
two possible cabling configurations. The difference depends on whether a
magazine tape subsystem is installed in position 6 of the SF200 storage
array.
The following steps are for cabling position 2 without a magazine tape
subsystem in position 6:
1. At the rear of the storage array, locate the DSSI I/O panel at the
bottom. Use a 3/16-inch flatblade screwdriver to loosen the two
captive screws at the right of the panel.
2. Swing open and remove the panel from the cabinet frame.
CAUTION
Use care not to disturb or damage power cords and DSSI
cables that are already connected to the DSSI I/O panel.
3. Remove the two Phillips screws that hold the panel blank in port 2
and port 10.
4. Install two 70-inch DSSI cables (part number BC21R–5L) in place of
the panel blanks you just removed in the previous step. Secure this
cable to the I/O panel with the two Phillips screws removed from the
blank panel.
5. Plug the other end of the 70-inch DSSI cable from port 2 into the
rightmost DSSI connector at the rear of the SF72.
6. Route this DSSI cable under the cable retainers on the right side of
the cabinet.
7. Plug the other end of the 70-inch DSSI cable from port 10 into the
leftmost DSSI connector at the rear of the SF72 (Figure 5–25).
8. Route this DSSI cable under the cable retainers on the left side of the
cabinet.
9. Plug two 108-inch DSSI cables (part number BC21Q–09) into ports 2
and 10 (Figure 5–25). Tighten the retainer screws with your fingers.