Installation guide

Installing the SF72 Storage Enclosure in an SF200 Storage Array 5–25
6. Check the DSSI ID switches on the OCP.
Open the door on the front of the OCP. Ensure that the DSSI
ID switches (the three rightmost switches) are set according to
Figure 5–12. If they are not, then use a pointed instrument to set
the switches to their correct configuration. Refer to Table 5–3.
NOTE
The leftmost switch (MSCP) should in the down or enabled
position at all times, unless you are instructed to change it to
the up or disabled position.
Table 5–3 DSSI ID Switch Settings (SF72 Only)
Positions 1, 2, 4, and 7
1
Left Rear (LR)
Left Front (LF)
Right Front (RF)
Right Rear (RR)
001
010
011
100
Positions 3 and 8 (Single-Host Only)
1
Left Rear (LR)
Left Front (LF)
Right Front (RF)
Right Rear (RR)
101
110
110
101
1
The switch settings for OCPs in these positions are 0 = down and 1 = up.