User manual
PS-2000B Series User Manual
5–3
Chapter 5 – Monitoring Features
External Input Signals
The RAS interface connector processes the following input signals.
For connector pin arrangements and electrical specifications, refer
to 1.4.2 RAS Interface.
General Signal Input (DIN)
General Signal Input is a general type of digital input and is used for detecting
external device alarms. 4 bits (DIN0 to DIN3) are assigned for this input.
Use the System Monitor Property to turn the monitoring feature ON/OFF and
enter detailed error processing settings.
The signal level of the general signal input (DIN) should be 1.5 seconds
or longer; otherwise, it may not be detected.
Remote Reset Input (RST)
This is the PS-B hardware reset signal sent from an external device. When this
signal is enabled, a forced hardware reset is triggered.
Use the System Monitor Property to turn the Remote Reset Input feature ON/
OFF, and enter detailed error processing settings.
.
External Output Signals
The RAS interface connector provides the following output signals.
For connector pin arrangements and electrical specifications, refer
to 1.4.2 RAS Interface.
General Signal Output (DOUT)
General Signal Output is a digital output signal for sending system status
information to external devices. 4 bits (DOUT0 to DOUT3) are assigned for
this output.
This feature can be controlled from an application via the System Monitor API-
DLL.
• The SMART Monitor can be performed for the hard disk connected to
the IDE only. The state of the hard disk connected via a USB or a
SCSI cannot be monitored.
• When using a Software Mirroring Utility PL-SM900 with Rev. C or
before, the SMART Monitoring can not perform.