User manual
Chapter 1 – PS-B Unit Basics
PS-2000B Series User Manual
1–10
1.4.3 DVI-D Interface
Pin No. Signal Name Pin No. Signal Name
1 TMDS DATA2- 13 NC
2 TMDS DATA2+ 14 NC
3 TMDS DATA2 SHIELD 15 GND
4 NC 16 Hot Plug Detect
5NC17TMDS DATA0-
6 DDC Clock 18 TMDS DATA0+
7 DDC Data 19 TMDS DATA0 SHIELD
8NC20NC
9 TMDS DATA1- 21 NC
10 TMDS DATA1+ 22 TMDS CLOCK SHIELD
11 TMDS DATA1 SHIELD 23 TMDS CLOCK+
12 NC 24 TMDS CLOCK-
24-pin (Female)
Inch-type screws #4-40UNC
1
8
17 24
9
Connecting the FP-3700T
When connecting Pro-face’s FP-3700T to a PS-B unit using the FP-DV01-100<10m>
cable, be sure to change the dip switch settings on the PS-B unit’s main circuit board.
Refer to the following figure when changing the settings. For details about dip switch
positions, refer to 1.3 PS-B Part Names and Features.
The factory settings for switches 1 to 4 are all OFF.
SW #4 : OFF → ON
*1 When SW4 is ON and used together with a second RGB monitor, the screen
display resolution is fixed to XGA.
• When using Pro-face’s FP Series, be sure to read that unit’s
User Manual prior to operation.
• When using a DVI-D monitor together with a second RGB
monitor, some RGB monitors may not be able to be used, so
please include a monitor test in your system testing.
• When using Pro-face’s FP-DV01-50<5m> cable, use this dip
switch’s default setting.
ON OFF Default
SW1
SW2
SW3
SW4
FP-3700T
*1
(with FP-DV01-100)
Different monitor
Reserved
All OFF
Reserved
Reserved
1 2 3 4
ON
OFF