User manual

PS-2000B Series User Manual
11
Preface
CE Marking Notes
The PS2000B-41 units are CE marked, EMC compliant products.
<These units comply with the following standards>
Safety
EN60950
EMI
EN55011 Group1 (Class A), EN61000-3-2, EN61000-3-3
EMS (EN61000-6-2)
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6,
EN61000-4-8, EN61000-4-11
If following requirements are not met, the PS-B may fail to meet EN60950 stan-
dard requirements.
The PS-B should be used as a built-in component of an end-use product.
The PS-B is intended for indoor use only.
When connecting the PS-B unit's power cord, be sure to use a cord that is
appropriate for the current and voltage used, and that has conductive wires that
are 0.75 mm2 or larger.
When an end-use product will include the PS-B, be sure to design the PS-B
unit's power cut-off switch as a separate disconnect device and locate it where
the operator can easily reach it.
There is a danger of explosion if the PS-B unit's backup battery is incorrectly
replaced. This battery should be replaced only with same or equivalent type
recommended by the manufacturer. Dispose of used batteries according to the
manufacturer's instructions.
Be sure the unit the PS-B is built into uses an EN60950 approved structure.