User manual

Preface
PS-2000B Series User Manual
10
UL/c-UL (CSA) Application Notes
The PS2000B-41 units are UL/c-UL (CSA) recognized products. (UL File No.
E171486). Please pay special attention to the following instructions when apply-
ing for UL/c-UL approval for machinery which includes any of these PS-B units.
Equipment with a PS-B mounted in it requires UL/c-UL (CSA) evaluation for the
combination of the PS-B and the equipment.
The PS-B conforms as a component to the following standards:
UL 60950, Third Edition (Standard for Safety of Information Technology
Equipment, including Electrical Business Equipment)
CSA-C22.2 No. 950-M95 (Standard for Safety of Information Technology
Equipment, including Electrical Business Equipment)
PS200B-41 (UL Registration Model: 3180005-01)
If the following requirements are not met, the PS-B unit may fail to meet UL/c-UL
(CSA) standard requirements.
The PS-B unit should be used as a built-in component of end-use product.
The PS-B unit is intended for indoor use only.
When connecting the PS-B unit's power cord, be sure to use a cord that is
appropriate for the current and voltage used, and that has 0.75 mm2 or larger
conductive wires.
When an end-use product will include the PS-B, be sure to design the PS-B
unit's power cut-off switch as a separate disconnect device and locate it where
the operator can easily reach it.
There is a danger of explosion if the PS-B unit's backup battery is incorrectly
replaced. This battery should be replaced only with same or equivalent type
recommended by the manufacturer. Dispose of used batteries according to the
manufacturer's instructions.
Be sure the unit the PS-B is built into uses an UL/c-UL (CSA) approved struc-
ture.