Installation guide

10
External Input Signal (Dual use of DIN, RST Input Port)
General Purpose Input (DIN)’s input level must be 1.5 seconds or longer to
be detected.
Be sure the voltage value between terminals is controlled via the input volt-
age, so that the PS-B is operated within its recommended range. If the input
voltage exceeds this range, a malfunction or PS-B damage may occur.
With Sink/Source input, even if DIN(-), and RST(-) are positive, and
DIN(+), RST(+) are negative, no problems are created. Be sure to oper-
ate the unit within the recommended voltage range.
Input Voltage DC12V to DC24V
Input Current
7mA
Operating Voltage ON voltage: 9V (min), OFF voltage:3V (max)
Isolation Method Via photocoupler
(Interface Circuit) (Connection Example)
+5V
R
PC357
1.8k
1/10W
D-sub 25 pin Connector
DC12V to
DC24V
DIN0(+), DIN1(+)
DIN2(+), DIN3(+)
RST(+)
Cable
1.8k
1/10W
R
switch or switching
device
No polarity - for Sink/
Source input
Pin No. Signal Name Pin No. Signal Name
1GND14GND
2 +5V (MAX. 100mA) 15 +5V
3 +12V (MAX. 100mA) 16 DIN3 (+)
4 NC 17 DIN3 (-)
5 DIN2 (+) 18 RST (+)
6 DIN 0 (+) 19 DOUT1 (-)
7 DOUT2 (-) 20 DOUT1 (+)
8 DOUT2 (+) 21 DOUT3 (-)
9 DOUT0 (-) 22 DOUT3 (+)
10 DOUT0 (+) 23 RST (-)
11 DIN2 (-) 24 DIN1 (-)
12 DIN 0 (-) 25 NC
13 DIN 1 (+)
RAS Interface
Dsub 25 pin (Male)
Screw Size: (4-40): Inch Type
When using No.2 (+5V) and No.3 (+12V) External Power Output, be
sure to use only the designated level of current. Not doing so could
couse a damage or a unit malfunction.
1 2 3 4 5 6 7 8 9 10 11 12 13
14 15 16 17 18 19 20 21 22 23 24 25
DIN0(-), DIN1(-)
DIN2(-), DIN3(-)
RST(-)