User`s guide

Server Management
4-13
Status
Normal OCP
Display
OCP Error
Display
Description of
Error Display/Action
System
voltages
Sys voltages OK Sys +12V = xxxV
Sys +5V = xxxV
Sys 3.4V = xxxV
Sys -12V = -xxxV
+12V is out of tolerance.
+ 5V is out of tolerance.
+3.4V is out of tolerance.
-12V is out of tolerance.
Action: Check that power supply cables
and connectors are connected correctly.
CPU voltages
CPU voltages OK VRM1 y.yyV=x.xxV
VRM2 y.yyV=x.xxV
VRM3 y.yyV=x.xxV
VRM4 y.yyV=x.xxV
Voltage Regulator Module (VRM) 1 should
be y.yy volts and is being measured at
x.xx volts.
VRM 2 should be y.yy volts and is being
measured at x.xx volts.
VRM 3 should be y.yy volts and is being
measured at x.xx volts.
VRM 4 should be y.yy volts and is being
measured at x.xx volts.
Action: Diagnose whether the VRM or the
CPU module is bad.
Memory size
information
xxxxxMB
System BIOS
revision
BIOS Vx.yy x = main version
yy = sub-version
8031 BIOS
revision
8031 Vx.yy x = main version
yy = sub-version