User`s guide
Server Management
4-12
OCP Status and Error Messages
Status
Normal OCP
Display
OCP Error
Display
Description of
Error Display/Action
CPU ambient
temperature
CPU1 temp=xxxC
CPU2 temp=xxxC
CPU3 temp=xxxC
CPU4 temp=xxxC
CPU1 over heat
CPU2 over heat
CPU3 over heat
CPU4 over heat
Temperature of CPU 1 is out of range.
Temperature of CPU 2 is out of range.
Temperature of CPU 3 is out of range.
Temperature of CPU 4 is out of range.
Action: Verify fans are operational.
Action: Check that heat sink is correctly
attached to the CPU chip.
Power supply
status
P/S1 OK
P/S2 OK
P/S1 fail
P/S2 fail
Power supply 1 is not working.
Power supply 2 is not working.
Action: Check that power supply cables
and connectors are connected correctly.
Fan status
Sys fans OK Sys fan 1 fail
Sys fan 2 fail
Sys fan 3 fail
Sys fan 4 fail
Fan 1 is not working.
Fan 2 is not working.
Fan 3 is not working.
Fan 4 is not working.
Action: Check that fan connectors are
connected correctly.
CPU status
6000MPn
n = CPU number
CPU1 fail
CPU2 fail
CPU3 fail
CPU4 fail
Internal defect of CPU 1 or internal
temperature exceeds the upper limit.
Internal defect of CPU 2 or internal
temperature exceeds the upper limit.
Internal defect of CPU 3 or internal
temperature exceeds the upper limit.
Internal defect of CPU 4 or internal
temperature exceeds the upper limit.
No CPU exists No CPUs are present in the server.
Action: Reboot server and check if the
failed CPU is still malfunctioning during
POST.
continued