User`s guide

Problem Solving and Troubleshooting
11-3
Server Troubleshooting
Problem Possible Cause Action
No response when the
server is turned on.
Server is not plugged in.
No power at the wall
outlet.
Main logic board failed.
Main logic board switches
incorrectly set.
CPU module has failed.
CPU module switches
incorrectly set.
Terminator card not
seated properly (1P and
2P configurations only).
Terminator card not
installed.
Side panels removed.
Power supply failed.
Turn off the server, plug it in, and then
turn it back on again.
Use another wall outlet.
Contact your Digital service
representative.
Set all appropriate switches.
Reseat the CPU module.
Make sure all switches are correctly
set.
Reseat terminator card.
Install terminator card.
Install side panels.
Contact your Digital service
representative.
continued