User`s guide

Installing Additional Memory
6-14
Memory Troubleshooting
The Prioris ZX 6000MP Series server POST can detect memory errors
when it boots. The error can be isolated to one of two SIMMs on the MLB
and memory modules 1 and 2.
The memory error message format is as follows:
<Type of error>: <Location>
Where:
Type of error: Correctable error
Uncorrectable error
Location: Main Logic Board J17/J18
J20/J21
J25/J26
J28/J30
Memory Module 1 (J22) J02/J03
J04/J05
J06/J07
J08/J09
J10/J11
J12/J13
Memory Module 2 (J23) J02/J03
J04/J05
J06/J07
J08/J09
J10/J11
J12/J13
Example:
Uncorrectable Error : Main Logic Board J17/J18
If a correctable error occurs, the BIOS will display: “Press <F1> to
resume” after the server boots.
If an uncorrectable error occurs, the server will halt after the memory test.