POST and Boot Messages
The POST displays messages to alert to errors in hardware, software, and firmware or to provide operating
information about the computer.
Each time the POST displays a message on the screen, the computer's speaker beeps twice. If an error
occurs before the monitor is initialized, specific beep codes sound to alert to a problem. The table below
lists a general grouping of system messages arranged by the POST countdown number. In addition, each
message is accompanied by text describing the message and in most cases, a recommended solution to the
problem.
NOTE
Italics indicate variable parts of a message such as memory addresses, hexadecimal
values, and so on. These messages can differ at each occurrence.
POST
Countdown
Number
Message
Number
Message
Solution
240 0007
No timer tick Replace main logic
board.
200 0001
Shutdown failure Replace main logic
board.
190 0009
Timer 2 failure Replace main logic
board.
180 0010
Keyboard stuck key
Keyboard controller
Keyboard clock line
Keyboard data line
Keyboard failure
Check the keyboard
connection. If the
connection is secure, the
keyboard or keyboard
controller might have
failed. Replace
keyboard.
170 0041
Mouse failure Check the mouse
connection. If the
problem persists, replace
the mouse.
160 —
640 KB base memory
0 KB extended
memory
150 0017
Time-of-day clock
stopped
Replace RTC.
100 0018
Invalid configuration
information
Run the SCU.
090 0011
Diskette drive failure Run the SCU. Check all
connections. If the
problem persists, replace
the diskette drive.
080 0015
Hard disk controller
failure
Run the SCU. Check all
connections. If the
problem persists, replace
the controller.