Technical data

Digital PRIORIS XL ServerDigital PRIORIS XL Server Service ProceduresService Procedures
MCS Logistics Engineering - NijmegenMCS Logistics Engineering - Nijmegen 4343
P
R
I
O
R
I
S
X
L
PRIORIS XL466 and 4100 Memory Configurations
Standard configuration of 8 MB
Maximum 128 MB
Only the configurations listed below are allowed.
Bank 0
Bank 1
Bank 2
Bank 3
Bank 4
Bank 5
Total
4 MB 4 MB
8 MB
Standard
4 MB 4 MB 4 MB 4 MB
16 MB
8 MB 8 MB
16 MB
4 MB 4 MB 8 MB 8 MB
24 MB
8 MB 8 MB 8 MB 8 MB
32 MB
16 MB 16 MB
32 MB
4 MB 4 MB 16 MB 16 MB
40 MB
8 MB 8 MB 16 MB 16 MB
48 MB
4 MB 4 MB 8 MB 8 MB 16 MB 16 MB
56 MB
16 MB 16 MB 16 MB 16 MB
64 MB
32 MB 32 MB
64 MB
4 MB 4 MB 32 MB 32 MB
72 MB
8 MB 8 MB 32 MB 32 MB
80 MB
4 MB 4 MB 8 MB 8 MB 32 MB 32 MB
88 MB
16 MB 16 MB 32 MB 32 MB
96 MB
4 MB 4 MB 16 MB 16 MB 32 MB 32 MB
104 MB
8 MB 8 MB 16 MB 16 MB 32 MB 32MB
112 MB
32 MB 32 MB 32 MB 32 MB
128 MB
PRIORIS XL560, 566 and 590 Memory Configurations
Standard configuration of 16 MB.
Maximum 192 MB.
Only the configurations listed below are allowed.
ECC memory: Only (2 x 16 MB) and (2 x 32 MB) are available.
Parity memory and ECC memory cannot be mixed together.
Bank 0 / 1
Bank 2 / 3
Bank 4 / 5
Bank 6 / 7
Total Memory
2 x 4 MB 2 x 4 MB
16 MB
2 x 8 MB
16 MB Standard
2 x 4 MB 2 x 8 MB
24 MB
2 x 4 MB 2 x 4 MB 2 x 4 MB
24 MB
2 x 4 MB 2 x 4 MB 2 x 8 MB
32 MB
2 x 8 MB 2 x 8 MB
32 MB
2 x 16 MB
32 MB
2 x 16 MB (ECC )
32 MB (ECC)
2 x 4 MB 2 x 8 MB 2 x 8 MB
40 MB