Technical data
Installing Disk and Tape Drives
6-4
Cables
The server is shipped with a wide SCSI cable with ten connectors connected to
the wide Adaptec 7880 SCSI controller on the main logic board to the CD-ROM
(option on some Prioris XLe 6000 Series configurations) and then to the two
5.25-inch drive bays and an active termination.
Installing Optional Drives
Your server has two drive bay areas. Optional drives such as a SCSI disk drive,
a SCSI CD-ROM, and a SCSI tape are installed in these drive bay areas. The
two drive bay areas are:
•
Front access drive bay area — This area has one 5¼-inch SCSI CD-ROM
drive (option on some Prioris XLe 6000 Series configurations) and one
diskette drive, and room for one narrow (50-pin) 5¼-inch half-height SCSI
device. Devices can include a CD-ROM drive or a tape drive.
•
Internal drive bay area — This area has room for four 3½-inch, 1.5-inch high
or six 3½-inch, 1-inch high wide SCSI-2 devices.