Adjustment Procedures
Belt, Platen Open, Adjustment (Figure 4–2)
1. Prepare the printer for maintenance (page 4–2).
2. Open the printer cover.
3. Remove the platen open belt cover (1) by squeezing the top and bottom
to release the plastic tabs from the slots in the side plate.
4. Loosen the motor mount screws (2).
5. Close the forms thickness lever all the way.
CAUTION
Too much tension on the platen open belt can cause the platen gap to
change, which can lead to premature wear of the platen, damaged
hammer tips, and poor print quality.
6. Using a force gauge, apply 10
± 1 pounds (44.48 ± 4.45 N) of tension to
the shank of the platen drive pulley (3), pushing away from the large
platen pulley.
7. Reduce tension to 5
± 1 pounds (22.24 ± 4.45 N) and torque the motor
mount screws (2) to 11
± 2 inch–pounds (1.24 ± 0.23 NSm).
8. Snap the platen open belt cover (1) into the slots in the side plate.
9. Return the printer to normal operation (page 4–3).