Instruction manual
5–48
Replacement Procedures and
Illustrated Parts List
Switch Assembly, Platen Interlock
Removal
1. Prepare the printer for maintenance (page 4–2).
2. Remove the paper path (page 5–29).
3. Fully close the forms thickness lever (position ‘A’).
4. Trace the platen interlock switch cable back to the controller board.
Remove tie–wraps as necessary to free the cable. (See cable routing
diagram on page A–10.)
5. Disconnect connector shell P107 from the controller board.
6. Remove the platen interlock cable connector from the connector shell
(page 5–8).
7. Remove the two #1 Phillips screws securing the platen interlock switch
assembly. (See Figure 5–14, page 5–67.)
8. Remove the platen interlock switch assembly from the switch bracket.
9. Remove the switch cable from the cutout in the right side plate.