Operating instructions

Satellite Operations Using a Hand-Held Radio
The following list of satellite operations can be initiated in the field using a hand-held radio keypad. All operation com-
mands must begin with the following keypad sequence:
*
9 followed by the 3-digit satellite address number. The com-
mand code is then entered, followed by additional digits which represent selected stations and/or run time values. All
station numbers from 19 must be entered with a preceding 0; i.e., station 1 is entered as 01.
Example: Confirm communication to the satellite by issuing a manual station start command as follows: Press
*
9, the
3-digit satellite address code, command code 7521 and 01 (station 1). The LED indicator on the decoder module should
turn off momentarily. An audible click should be heard from the station relay and the corresponding station output LED
should turn on. Visually check for sprinkler operation. To step forward through the stations, press
*
1; to step back
through the stations, press
*
2. To terminate the test, use command code 7520.
Command Code Operation Description
7510 Turns off individual stations; e.g., 7510 01 02 40 turns off stations 1, 2 and 40.
7511 Turns on individual stations; e.g., 7511 01 02 40 turns on stations 1, 2 and 40.
7512 Syringes individual stations for a predetermined number of 30-second intervals (already defined
in the satellite); e.g., 7512 01 02 turns on stations 1 and 2 for 30-second intervals.
7513 Disables individual stations; e.g., 7513 01 03 disables stations 1 and 3. After this command,
on and off commands will be ignored for stations 1 and 3 until the stations are re-enabled.
(See 7514.)
7514 Enables individual stations; e.g., 7514 01 03 enable stations 1 and 3.
7515 Sequentially syringes a specified station number range; e.g., 7515 10 20 will syringe stations
10 through 20 sequentially.
7516 Sequentially syringes individual stations; e.g., 7516 10 11 will syringe stations 10 and 11.
Multiple syringe groups can also be run. Enter two dashes between stations to designate sepa-
rate syringe groups; e.g., 7516 10 11 - - 22 24 26 28 will run two sequential syringes at the same
time on stations 10 and 11 and stations 22, 24, 26 and 28.
7517 Turns on individuals stations for a specified number of hours, minutes and seconds; e.g.,
7517 01 30 00 23 24 25 turns stations 23, 24 and 25 on for 1 hour, 30 minutes and no seconds.
7518 Turns on individual stations for a specified number of minutes; e.g., 7518 10 23 24 25 turns
on stations 23, 24 and 25 for 10 minutes.
7520 Turns off a sequential station run operation (initiated by command code 7521).
7521 Turns on a sequential station run operation; e.g., 7521 01 turns on station 1. To step forward
through the stations, press
*
1; to step back through the stations, press
*
2.
7524 Turns on individual stations as switches; i.e., does not simultaneously energize the pump.
Note: Will not turn off the pump if already running. E.g., 7524 25 35 45 turns on stations 25, 35
and 45 without energizing the pump.
7525 Turns on individual stations as switches for a time given in minutes; i.e., does not simulta-
neously energize the pump in this command string, the run time is entered first, followed by the
station numbers; e.g., 7525 25 05 42 turns on stations 5 and 45 for 25 minutes without energiz-
ing the pump.
7526 Turns on individual stations as switches for the time given in hours, minutes and sec-
onds. In this command string, the run time is entered first, followed by the station numbers; e.g.,
7526 02 30 45 25 26 27 turns on stations 25, 26 and 27 for 2 hours, 30 minutes and 45 seconds.
7540 Turns off all stations (this satellite only).
7543 Disables all stations in all satellites (rain shutdown). Note: Satellite address code is not used
with 7543 or 7544 command codes. The stations will not respond to any further commands until
enabled.
7544 Enables operation of all stations in all satellites. See Note above.
7546 Sequentially syringes all stations for a set length of time; e.g., 7546 turns on all stations for
the predetermined number of 30 second intervals as defined in the syringe time.
8000 Disables pump start.
8001 Enables pump start to be assigned to a station; e.g., 8001 48 assigns pump start to station 48.
8003 00 Disables operation and turns off all stations in the satellite with sequential shutdown.
8003 01 Enables operation of all stations in the satellite.
8004 Changes the password; e.g., 8004 7531 6108 will change the factory default password (7531)
to 6108.