Troubleshooting guide
Specific Conversion Box Commands
A-2
Command_n Syntax
The command_n syntax is as follows:
(Operator Type Family
/ Attribute_1
/ Attribute_n
Value)
Where:
Operator
is used to indicate the operation type;
assign or reset.
Type Family
designates the parameter which is to be configured.
Attribute
specifies the argument which is used with Type
Family parameter.
Value
is the quantifier component or a constant parameter
Note: There must be a space between the operator and type and also
between the attribute and the value parameters.
Each part is described in more detail in the sections that follow.
Conventions
• The upper and lower cases are allowed in the syntax.
• Additional spaces, Carriage Return CR, and Line Feed LF are only
allowed between:
- Operator and Type Family parameters
- Type Family and Value parameters
- Attribute (s) and Value parameters.
• The Attribute(s) can be placed in any order between Type Family and
Value parameters.
Examples:
(= printer/protection/horizontal #ON) or
(= printer/horizontal/protection #ON)
• Unlimited commands are allowed between the Introducer Command
and the String Terminator.
Example:
DCS 58 ; 1i (= printer/model #LN17) (= emulation #transparent) ST