Troubleshooting guide

Configuring and Operating
2-5
ENGLISH
Setting PPL3 or LN03plus Mode
Switch 11 (H): This dipswitch setting controls whether the Convert
Box in data conversion box emulates a DEC PPL3 printer or an
LN03plus. The ON position is for the LN03plus mode, and the OFF
position is for the DEC PPL3 mode.
ON
1234567891011 12
ABCDEFGHI
Setting Autosensing or Transparent Mode
Switch 12 (I): This dipswitch setting controls whether the Convert
Box operates in Autosensing mode or in Transparent mode. See
Preface for the description of those two modes.The ON position is for
the Transparent mode, and the OFF position is for the Autosensing
mode.
ON
123456789101112
ABCDEFGHI