Troubleshooting guide

Installing the Conversion Box
1-4
The default settings for the conversion box serial
communications are as given in the following table:
Box Serial Communication Default Settings
Parameters Value
Baud rate 9600
Bit size 8
Parity disabled
Buffer Flow Control Xon/Xoff
2. Check the paper format dispswitch setting on the box.
Switch 10 (G) on the dipswitch should be set to On for US Letter
size or Off for A4 (as used in most European countries). The
paper format should match the size of paper in your target printer.
3. Make the box settings and the printer settings according to
your printing application:
See the following table
Convert Box and Printer Settings
to
configure both the convert box and your printer according to your
printing application. For example, if you print only DEC PPL3
jobs, the convert box operates in Data Conversion (PPL3) mode,
and the recommended settings are the following:
Convert Box Settings
Feature Setting
PPL3/LN03+: PPL3
Autosensing/Transparent: Autosensing
Printer Settings
Feature
Setting
Parallel Port:
Bi-directional On
System Language:
PCL or Autosensing