ENGLISH Convert Box for DECLaser Installation and Configuration Guide Order Number: EK-LNCPB-UG-002 Digital Equipment Corporation
Second Edition, August 1996 Digital Equipment Corporation makes no representations that the use of its products in the manner described in this publication will not infringe on existing or future patent rights, nor do the descriptions contained in this publication imply the granting of licenses to make, use, or sell equipment or software in accordance with the description.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Any changes or modifications made to this equipment may void the user's authority to operate this equipment.
CE Mark • Directive 89/336/EEC on the Electromagnetic Compatibility based on: EN55022 Class B EN50082 • Richtlinie 89/336/EWG zur elektromagnetischen Störfreiheit, basierend auf: EN 55 022 Klasse B EN 50 082 • Directiva 89/336/EEC referente a Compatibilidad electromagnética basada en: EN55022 Clase B EN50082 • Directive 89/336/CEE relative à la compatibilité électromagnétique sur la base de: EN55022 Classe B EN50082 • Direttiva 89/336/EEC sulla compatibilità elettromagnetica basata su: EN55022 Clas
ENGLISH Contents Introduction .........................................................................................v Features ..............................................................................................vi Operating Modes .............................................................................. vii The Data Conversion mode....................................................... vii The Bi-directional Communications Transparent mode ............ vii The Autosensing mode ...........
Contents Setting PPL3 or LN03plus Mode.............................................. 2-5 Setting Autosensing or Transparent Mode ................................ 2-5 Dipswitch Settings ........................................................................... 2-6 Software Configuration .................................................................... 2-7 Specific Conversion Box Commands ....................................... 2-7 Digital ANSI Protocol Configuration Command ......................
Factory Default Configurations Dipswitch Configuration ..................................................................B-1 Software Configuration.................................................................... B-2 Technical Characteristics Character Set List ............................................................................ C-2 Conversion Box Interfaces ...............................................................C-3 Parallel Interface......................................................
ENGLISH Preface Introduction Convert Box for DECLaser is a conversion box designed to print on new Digital laser printers, jobs originally intended for DEC PPL3 printers. The DEC PPL3 printer is replaced by the box connected to a target printer as shown in the before and after situation in the following figures. This box stands between the host computer and the targeted Digital printer. DEC PPL3 is the Digital ANSI-Compliant Printing Protocol which includes functions for page printers.
Preface Features The box has the following features: Compatibility to Digital PPL3 ANSI Protocols The conversion box with the printer replaces Digital PPL3 printers without degrading the overall performances. The box emulates the following DEC PPL3 printers: DECLaser 1100, DECLaser 2100/2200, DECLaser 3200, LN03 Plus. Ease-of-use Simple configuring and operating. Separate Power Supply The conversion box is powered via an external AC/DC adapter.
Target Printer Detection The box is capable of detecting which printer is attached to the parallel port. This allows addressing of the specific printer features. The following printers are supported: DECLaser 3500, DECLaser 5100, LN17.
Preface is enabled and so that the printer system language supports reporting and job control (PJL or PostScript, for instance). In this mode the Convert Box may be used in a DCPS (DECPrint Supervisor) environment provided that the printer connected to the parallel port is set to the PostScript system language. The Autosensing mode In this mode, the Convert Box detects whether the data received through the serial input port is a DEC PPL3 job or a PostScript job.
Chapter 3 - Troubleshooting This chapter contains a troubleshooting guide for problems which may occur, and tells you how to solve them. Chapter 4 - Target Printers Information This chapter details information about the supported printers and their default settings. Appendices A-C The appendices describe the conversion box specific commands, the default configuration, the serial and parallel technical characteristics. There is also an index.
ENGLISH 1 Installing the Conversion Box Unpacking the Conversion Box 1. Open the carton and remove all parts 2.
Installing the Conversion Box Conversion Box Description The figure below shows the Conversion Box and its main features which are described in the following: Button for reset mode and internal tests purposes Two indicators showing power and box operating states MMJ6 connector for serial communication, RS232 type, to connect to the host computer AC/DC adapter socket Dipswitch bank for configuration Parallel Centronics connector, for connection to the target printer 7 1 2 3 4 5 6 The Co
ENGLISH Installing the Conversion Box Installing the Conversion Box The box is installed in three stages: 1. Pre-installation Checks 2. Connecting 3. Power on and Testing In many instances there will be no need to configure the box and you can simply connect the box, power on and go. However, it might be necessary to configure the box as described in Chapter 2.
Installing the Conversion Box The default settings for the conversion box serial communications are as given in the following table: Box Serial Communication Default Settings Parameters Value Baud rate 9600 Bit size 8 Parity disabled Buffer Flow Control Xon/Xoff 2. Check the paper format dispswitch setting on the box. Switch 10 (G) on the dipswitch should be set to On for US Letter size or Off for A4 (as used in most European countries).
ENGLISH Installing the Conversion Box Convert Box and Printer Settings Printing Application Convert Box Operating Mode Convert Box Settings Printer Settings Autosensing / Transparent PPL3 / LN03+ Parallel Port System Language Printing DEC PPL3 Jobs Data Conversion (PPL3) Autosensing PPL3 Bidir. On PCL or Autosensing Printing LN03+ Jobs Data Conversion (LN03+) Autosensing LN03+ Bidir. On PCL or Autosensing Printing PostScript Jobs - Transparent Transparent - Bidir.
Installing the Conversion Box Printing Application Printing PPL3 or PostScript jobs alternatively (non DCPS environment) Convert Box Settings Printer Settings Autosensing / Transparent PPL3 / LN03+ Parallel Port System Language Jobs are separated by an idle time Autosensing Autosensing PPL3 or LN03+ Bidir. On Autosensing Jobs are NOT separated by an idle time Data Conversion or Transparent alternatively. Selection made by software configuration prior to each job. See Appendix A - - Bidir.
Stage 2 - Connecting the Conversion Box Provided that the pre-installation checks do not require any configuration, you can now connect the pieces of equipment together in the following sequence: AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Note: Ensure that all equipment is switched off and the power cables removed from the mains power outlet before you connect any cables.
Installing the Conversion Box Connecting the Conversion Box AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Note: The figure shows the connection without using the flat ribbon cable, and with direct connection through the MMJ6 connector.
Stage 3 - Power on and Testing Having successfully completed stages one and two, you can now power on the box and the printer and run some tests to determine if all is well. 1. Apply power to the box by connecting the AC/DC adapter to the mains power outlet. The mains socket outlet must be easily accessible. The On indicator on the conversion box should light. 2. Switch the printer ON, and wait the printer ready indication 3.
Installing the Conversion Box Operating the Box The box operation should mainly be transparent to the user. However, there are tests that you can run and indications that you should be aware of. These are described in the following two tables.
ENGLISH 2 Configuring and Operating Configuring the Conversion Box If the default settings of the box and your host and printer do not match, you will need to configure the box. You can do this primarily through changing the dipswitch settings on the box (dipswitch configuration). In addition to this, you can use control commands issued from the host that can override or dynamically change the dipswitch settings or set other parameters (software configuration).
Configuring and Operating Dipswitch Configuration The dipswitch settings control the main configuration parameters of the box. The box is delivered with default settings that you might have to change according to your host and printer parameters which you check before installing the box.
ENGLISH Configuring and Operating Setting the Serial Communications A B C D E F G H I ON 1 2 3 4 5 6 7 8 9 10 11 12 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Note: Make sure those parameters exactly match the ones of the serial host communication.
Configuring and Operating Setting Hexdump Mode A B C D E F G H I ON 1 2 3 4 5 6 7 8 9 10 11 12 Switch 9 (F):Diagnostic feature which allows the user to analyze all the bytes transferred from the computer to the box. Each byte transmitted is printed in hexadecimal format, allowing the user to check the data codes received.
Setting PPL3 or LN03plus Mode Switch 11 (H): This dipswitch setting controls whether the Convert Box in data conversion box emulates a DEC PPL3 printer or an LN03plus. The ON position is for the LN03plus mode, and the OFF position is for the DEC PPL3 mode. A B C D E F G H I ON 1 2 3 4 5 6 7 8 9 10 11 12 Setting Autosensing or Transparent Mode Switch 12 (I): This dipswitch setting controls whether the Convert Box operates in Autosensing mode or in Transparent mode.
Configuring and Operating Dipswitch Settings A B C D E 38400 19200 Baud Rate 9600 4800 2400 1200 600 300 Bit Size 8 7 Enable Parity Disable Even Odd Buffer Control Autowrap Hexdump Paper Size LN03+ PPL3 Transparent Autosensing XON/XOFF DTR ON OFF ON OFF US Letter A4 ON OFF ON OFF ON 2-6 OFF Default F G H I
Software Configuration The dipswitch setting is designed to ensure a proper installation of the box. However, it does not cover all the possibilities offered by the conversion box. To that end, a more application oriented software based configuration facility, has been implemented. The software configuration is performed by sending control commands to the conversion box from the host.
Configuring and Operating Digital ANSI Protocol Configuration Command The Digital ANSI protocol has a command called DECFNVR which is designed to perform a custom configuration of the conversion box. DECFNVR can be used to set the states of the following parameters: • Line Feed Mode • Carriage Return Mode • Character Set • Number of copies Use of DECFNVR 1. Send to the conversion box one or more of the Digital commands corresponding to the features listed above 2.
ENGLISH 3 Troubleshooting Resetting the Box You can recover the power up default parameters by resetting the conversion box. This procedure is recommended when the printer gives unexpected results, and you do not succeed in solving your problem. To reset the box, press and hold for five seconds the reset button until the Status indicator starts blinking quickly.
Troubleshooting Solving Problems Installation Problems Missing or damaged parts • Contact your dealer immediately. The conversion box does not power on • Make sure the AC/DC adapter is inserted correctly into the conversion box and to the power outlet. • Check that power is supplied through your power outlet. The configuration printout does not print at all • Check the conversion box is securely connected to the printer parallel connector.
The Configuration Sheet does not reflect the correct printer connected (“Not identified” printed next to the target printer name) • Check that the printer is listed as a supported target printer. • Check that the parallel port of the printer is set for bi-directional communications (IEEE 1284). Printing Problems Printing after first power-up is not the expected one • Run the configuration printout to verify the current settings. See the default printer configurations given in Chapter 4.
Troubleshooting The conversion box does not print data coming from the host • Check that the serial communication connection is correct. The Status indicator should light when receiving data. • Check the printer display to verify data is received. If so, try to eject the page by pressing the Form Feed button of the printer, and verify that your application terminates the job by a Form Feed command. For that, you can run a Hexadecimal Printout (see Chapter 2 for details).
Printing distorted or incomplete • Check you have enough resident memory available in your printer (at least 2 Mb) and that the printer set-up is correct. «Page Protect» parameter, if it exists, should be set (see Chapter 1 for details). Printing appears with a bad contrast • Check the printer setup parameter «Enhancement» setting, if it exists. Printing in general is incoherent • Reset the conversion box by pressing and holding the reset button for five seconds.
ENGLISH 4 Target Printers Information Printers Supported by the Conversion Box • LN17 • DECLaser 3500 • DECLaser 5100 Printer Parameters to Configure For most applications, the factory default configuration of your printer should work directly with the conversion box. However, depending on the application type you want to run, it may be necessary to change the parameters and set up your printer accordingly.
Target Printers Information Digital LN17 Parameters Interaction with the Box and Recommended Setting Menu Item Interaction / Recommended Setting PCL Copies Yes (Overridden by Digital Commands) AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Font Source No AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Font Number No AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Pitch AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA A No AAAAA
Menu Item ENGLISH Target Printers Information Interaction / Recommended Setting PostScript Yes Interface / Parallel Port Enable Must be On AAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Port Timeout Yes / 30 seconds ¹ AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA System Language AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA A Yes AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
Target Printers Information DECLaser 3500 Parameters Interaction with the Box and Recommended Setting Menu Item Interaction / Recommended Setting Paper Yes / Must be set according to the paper format used and dipswitch setting Output Options Print Resolution No AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Print Enhancement Yes (when sending graphic data) / OFF AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Number of Copies No (except whe
ENGLISH Target Printers Information DECLaser 5100 Parameters Interaction with the Box and Recommended Setting Menu Item Interaction / Recommended Setting Feeders Yes / Must be set according to the paper format used and dipswitch setting PostScript No PCL Resolution AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA A NoAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Enhancement No AAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A Specific Conversion Box Commands General Rules The specific conversion box commands (command_n) are introduced with the introducer command DCS 58 ; 1i, and terminated by the String Terminator ST. The introducer and string terminator can be given in hex form as necessary. Both methods are shown in the following table: ASCII Hexadecimal value DCS 58 ; 1i Command_n ST 90 35 38 3B 31 69 Command_n 9C APPENDICES These commands can be sent from any text terminal editor.
Specific Conversion Box Commands Command_n Syntax The command_n syntax is as follows: (Operator Type Family / Attribute_1 / Attribute_n Value) Where: Operator is used to indicate the operation type; assign or reset. Type Family designates the parameter which is to be configured. Attribute specifies the argument which is used with Type Family parameter.
Specific Conversion Box Commands Specific Conversion Box Parameters Operator Parameter The Operator parameter can take two values: Used with the other Type Family parameters as given in the following table to assign values. Reset Can be used with all Type Family components to return parameters value to their factory default.
Specific Conversion Box Commands Type Family Parameters The following table identifies the Type Family parameters that can be used.
Specific Conversion Box Commands Type Family Timeout Attribute Serial Parallel Device_id Value 0 to 1000 (default= 20 seconds) 0 to 1000 (default= 30 seconds) 2 #Default (default) #LA100 #LQP02 #LN03plus #PPL3 1 Model: Since the Convert Box detects which printer is connected automatically, this attribute is used only when the connected printer is unknown or when the Convert Box is unable to detect it.
Specific Conversion Box Commands Commands List The tables in this section show examples of the box specific commands (command_n) and describes their meaning. For simplification in the examples shown below, the Introducer DCS (9OH) and String Terminator ST (9CH) sequences are not included. Do not forget to insert them when sending the complete command. Using the Reset Operator The Reset operator recalls the factory default values for the Type family parameter selected.
Specific Conversion Box Commands Emulation Meaning (= Emulation #PPL3) Translates DEC PPL3 protocol to be interpreted by the target printer. (= Emulation #LN03plus) Translates Digital LN03plus protocol to be interpreted by the target printer. (= Emulation #Transparent) All data coming into the serial input of the conversion box simply go through the printer via the parallel port without any modifications.
Specific Conversion Box Commands Printer Command Syntax Meaning 3 (= Printer/Model #LN17) 1 Selects printer as LN17 3 (= Printer/Model #DEC3500) 1 Selects printer as DEC3500 3 (= Printer/Model #DEC5100) 1 Selects printer as DEC5100 (= Printer/Protection/Horizontal #ON) Solves incorrect horizontal print positioning (= Printer/Protection/Vertical #ON) Solves incorrect vertical print positioning (= Printer/Protection/Fonts #ON) Avoids font deselection (= Printer/Offset/Vertical numeric val
Specific Conversion Box Commands Command Syntax Meaning (= Device_id #Default) Set the device identificator to PPL3. (= Device_id #LA100) Set the device identificator to LA100. (= Device_id #LN03plus) Set the device identificator to LN03plus. (= Device_id #LQP02) Set the device identificator to LQP02.
Specific Conversion Box Commands Printing DEC PPL3 or PostScript Jobs Alternatively When DEC PPL3 jobs and PostScript jobs are not separated by a sufficient idle time, the Convert Box cannot switch from the data conversion mode to the transparent mode automatically, even if the Autosensing mode is set. Therefore, prior to each job, it is necessary to set the appropriate mode by sending software configuration commands according to the job to be printed.
Specific Conversion Box Commands Sending the Appropriate Sequences in a VMS Environment The following provides guidelines on two methods of sending the appropriate sequences via the Convert Box depending on the type of job to be printed. The two methods involve the setup modules mentioned in the above section (PPL3.TXT,LN03.TXT and PS.TXT) which must be created in a device control library using the LIBRARY command. See detailed information on the VMS commands in the appropriate VMS documentation.
Specific Conversion Box Commands Setting a Print Queue for PPL3 Jobs The Form PRT$PPL3 is defined by the command DEFINE/FORM/SETUP=(PPL3) PRT$PPL3 The Print Queue ConvBox_PPL3 is set by the command INITIALIZE/QUEUE/ON=print_port/DEFAULT=(FORM=PRT$PPL3) ConvBox_PPL3 Then each PPL3 job is printed by the command PRINT/QUEUE=ConvBox_PPL3 Filename Setting a Print Queue for LN03plus Jobs The Form PRT$PPL3 is defined by the command DEFINE/FORM/SETUP=(LN03) PRT$LN03 The Print Queue ConvBox_LN03 is set by the c
B Factory Default Configurations Dipswitch Configuration The conversion box has two factory default configurations; US and European. These configurations differ by the paper format setting of switch #10 (G) only. The factory default settings are as follows: A B C D E F G H I ON 1 2 3 4 5 6 7 8 9 10 11 12 APPENDICES For the European versions, switch #10 (G) will be in the off position.
Factory Default Configurations Software Configuration Software configuration is performed using specific conversion box and Digital ANSI protocol commands. They can override or dynamically change the dipswitch settings.
Factory Default Configurations Digital ANSI Protocol Commands - Factory Default Configuration Features Value Vertical Spacing (Lpi) Font dependent 6.25 for DEC Built-in AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Horizontal Spacing (Cpi) Font dependent: - 10 for DEC Built-in US Format - 10.
Factory Default Configurations Reset to Power Up default The power up state of the box for the following features can be different from the factory default, when they are used along with the DECFNVR command. − LF / New Line − CR / New Line Mode − Character Set (G0 = GL) − Character Set (G2 = GR) − DECSNC (Number of Copies) This also applies when the RIS and DECSTR reset commands are used.
C Technical Characteristics Main Characteristics Interfaces Input serial (RS 232 type) MMJ6 type Output parallel (Centronics - bi-directional Nibble 1284 mode) Resident Fonts RAM Electrical Characteristics Operating Environment Certification Physical Characteristics DEC PPL3/ LN03plus - Built-in family - Courier family - Courier 10 pts, 10 pitch - Courier 10 pts, 10.
Technical Characteristics Character Set List • US ASCII • DEC Supplemental • DEC Technical • VT100 Line Drawing (DEC Special Graphics) • National Replacement Character Sets (NRC sets): − British − Dutch − Finnish − French − French Canadian − German − Italian − JIS Roman − Norway/Danish − Spanish − Swedish − Swiss − ISO Norway/Danish − ISO Latin 1 Supplemental − Legal − Hebrew character sets: DEC 7-bit Hebrew DEC Hebrew supplemental ISO Latin Hebrew supplemental C-2
Technical Characteristics Conversion Box Interfaces Parallel Interface The conversion box can be directly connected to the parallel input port of the target printer, or through the flat cable delivered in the kit.
Technical Characteristics The following table details the signal to pin assignment for the interface and the direction of the signal.
Technical Characteristics Serial Interface The serial communication port is a 6 pin modular MMJ, RS232 standard interface. The serial cable must be a Digital connect cabling system with snap-in connector and a flat 6 conductor cable. 1 2 3 4 5 6 Serial Interface Pin Assignment The following table details the signal to pin assignment for the interface and the direction of the signal.
Technical Characteristics Configuration Printout The configuration printout can be used to show you the default settings or if you have changed the configuration of the box, it will show you the current configuration. The printout will show: − Firmware revision level − Dipswitch setting − Software setting − Digital ANSI protocol commands settings To run the configuration printout, press the button once. TM CONFIGURATION SHEET Revision Level V2.
Technical Characteristics AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Note: In the Configuration Sheet, the target printer listed under the General title is identified by the Convert Box automatically. In case the Convert Box is not able to identify which printer is connected to the parallel port, the tag “(Not Identified)” is printed next to the Target Printer name which is defined by default.
Technical Characteristics Fonts List Printout The printout will show: − Resident fonts − Down line loaded fonts To run the font lists printout, press the button twice in a row. TM Convert Box for DEClaser FONT LIST Revision Level Vl.
ENGLISH Index Index A AC/DC adapter vi, 1-2 Autosensing capabilities vi Autosensing mode viii B Bi-directional Communications Transparent Mode vii Button Functions 1-10 C Character Set List C-2 Command_n Buffer size commands A-6 command List A-6 Device_id commands A-9 Emulation commands A-7 operator parameters A-3 Printer commands A-8 syntax A-2 Time out commands A-8 type family parameters A-4 usage conventions A-2 Configuration dipswitches 2-2 software 2-7 Configuring autowrap mode 2-3 conversion Box
D I Data Conversion Mode vii DCPS DECprint Supervisor vi DECFNVR about 2-8 DECLaser 3500 parameters 4-4 DECLaser 5100 parameters 4-5 Default Conversion box specific commands B-2 Digital ANSI commands B-3 Digital ANSI Configuration Command 2-8 Digital Services 3-5 Dipswitch configuring 2-2 Dipswitch Settings autowrap mode 2-3 hexdump mode 2-4 paper format 2-4 serial communications parameters 2-3 Installation checklist 1-3 problems 3-2 procedure 1-3 Interface parallel - pin assignments C-3 parallel charact
T Serial Communication Default Settings 1-4 Serial Interface C-5 Setting autowrap mode 2-3 hexdump mode 2-4 paper format 2-4 serial communications parameters 2-3 Setting Autosensing or Transparent Mode 2-5 Setting PPL3 or LN03plus Mode 2-5 Software Commands Digital ANSI protocol commands 2-8 specific box commands 2-7 Software Configuration 2-7 Specific Box Commands 2-7, A-1 Buffer size commands A-6 command_n syntax A-2 commands list A-6 conventions A-2 Device_id commands A-9 Emulation commands A-7 general