Load <Paper Size>
Description The PageSize is set to 2 (PCL default is 2) and the requested paper does not reside
in the printer. If the requested paper is not inserted prior to the Paper Select Wait time-out, the
job prints as best it can from the default paper tray. Pressing the <Select> button prior to the
Paper Select Wait time-out also prints the job as best it can from the default paper tray.
Detection. By the Operating System.
Printer Response.
1) Save current job.
2) Sound beeper 5 times.
3) Hold present job until correct paper size is inserted or time-out occurs.
4) <Select> uses the default tray and paper size.
5) Normal operation.
Service Action Required.
None, but if the message does not go away after proper paper has been loaded, go to Sections
6.3.9, 6.3.10, 6.2.11, and 6.2.13.
Lower Tray Empty
Description The lower paper tray is detected as being empty. Normal operation does not
continue until the lower tray is replenished with paper. NOTE: This message only appears if an
auxiliary tray is installed on the unit.
Detection. By the Operating System.
Printer Response.
1) Save current job.
2) Sound beeper 5 times.
3) Hold present job until paper is replenished.
4) Normal operation.
Service Action Required.
None, but if the message does not go away after paper has been added, go to Section 6.2.11
Paper Cassette is out of Paper
and 6.3.10
No Paper Sensor Failure.
Lower Tray Out
Description The lower paper tray is detected as being out of the unit. Normal operation does not
continue until the lower tray is replaced. NOTE: This message only appears if an auxiliary tray is
installed on the unit.
Detection. By the Operating System.
Printer Response.
1) Save current job.
2) Sound beeper 5 times.
3) Hold present job until tray has been replaced.
4) Normal operation.
Service Action Required.
None, but if the message does not go away after paper tray has been added, go to Section
6.3.13
Paper Size Switch Failure.