Chapter 13: Removal and Replacement Procedures - Drive and Xerographic Modules
13-7
RRP 5.3 CRU Actuator Assembly
Removal
1. Open the Front Cover.
2. Remove all of the covers.
3. Remove the CRU.
4. Remove the Fuser Assembly (RRP 4.1).
5. Remove the controller (ESS). (RRP 6.2)
6. Remove the ESS enclosure (RRP 6.1).
7. Remove the Interconnect PWB enclosure (with PWB) (RRP 6.3).
8. Remove the CRU Sensor PWB (RRP 5.2).
9. Pull up on the Actuator Assembly to remove it from the ROS .
Replacement
1. Reinstall the CRU Sensor Actuator and Spring.
NOTE: Reattach the spring so it provides the proper return action for the
Actuator.
2. Reinstall the CRU Sensor.
3. Reinstall the Interconnect PWB enclosure (with PWB).
4. Reinstall the ESS enclosure.
5. Reinstall the controller
6. Reinstall the Fuser Assembly.
7. Reinstall the covers.
8. Reinstall the CRU.