Specifications
Chapter 11: Removal and Replacement Procedures --- Paper Transportation
11-19
RRP 3.9 Inlet Chute Assembly
Removal
1. Open the Front Transport Assembly.
2. Remove the Inlet Chute Assembly from the Pick–Up Roll by holding the chute at both sides
of the near edge, and rotating the Assembly back while pulling up .
CAUTION:
Do not touch the surface of the BTR Assembly.
3. Disconnect P/J 120 (Registration Sensor) from the bottom of the Assembly.
4. Remove the tapped 6mm gold screw securing the black wire to the resistor on the bottom of
the Assembly.
Replacement
1. Position the Inlet Chute Assembly near the Pick–Up Roll Assembly.
2. Plug in P/J 120 and secure the black wire with a tapped 6mm gold screw.
3. Align the tabs on each end of the Inlet Chute Assembly with the locating bosses on the Pick–
Up Roll Assembly .
4. Press the Inlet Chute Assembly onto the Pick–Up Roll Assembly. It will snap into place.
NOTE: Position the Inlet Chute in front of the Inlet Spring. Position the Lower
Chute Assembly mylar strips so they ride on top of the Take–Away Roll
Assembly.