Specifications

Chapter 7: Using the Diagnostic Tool
7-31
Configuration Mode code table
Code LCD DISPLAY MESSAGE
(Function of the routine)
Parameters [Factory default]
Contents of the parameter
Are
changes
possible?
0 CONFIGURATION
(Sets the printer configuration)
0~F (16 steps) [N/A]
When you convert the HEX notation 0~F
to the binary values b0, b1, b2, and b3,
the parameters mean:
b0=Paper size 0=Japanese
1=International
b1=Fan Alarm 0=N/A
1=Available
b2=MBF 0=N/A
1=Available
b3=Toner Sensor 0=N/A
1=Available
NO
1 RESOLUTION
(Set the print resolution)
0~7 (8 steps) [N/A]
0=240 dpi 5=300/240 dpi (sw)
1=300 dpi 6=400/300 dpi (sw)
2=400 dpi 7=640/300 dpi(sw)
3=480 dpi 8=400/240i (sw)
4=600 dpi (sw)=switching
NO
2 LD POWER
(Sets the intensity of the laser
output)
This function is also available in
User Mode
0~4 (5 steps) [21]
0=Minimum laser output. Produces the
lightest print density
4=Maximum laser output. Produces the
darkest print density
YES
3 REG.PROCESS 1
(Sets the lead edge registration
for paper fed from Tray 1)
0~F (16 steps) [8]
0=Narrowest lead edge registration gap
F=Widest lead edge registration gap
(approximately 0.56mm per step)
YES,
depending
on the
model of
printing
used