Specifications

Chapter 7: Using the Diagnostic Tool
7-18
DG 86 SOLENOID TRAY 2
This Diagnostic code tests the Optional Feed Solenoid.
To run DG 86:
1. Enter Diagnostics Mode.
2. Repeatedly press [2] until the LCD displays
DG 86.
3. Press [1] to start the test.
4. Verify that when you press [1], the Optional Feed Solenoid actuates.
5. To Exit DG 86, repeatedly press [2] to cycle the LCD to
DG 00 Exit
Diagnostics.
6. Press [1] to exit DG 86.
DG 84 T CLUTCH UPPER
This Diagnostic code tests the Feed Assembly Turn Solenoid.
To run DG 84:
1. Enter Diagnostics Mode.
2. Repeatedly press [2] until the LCD displays
DG 84.
3. Press [1] to start the test.
4. Verify that when you press [1], the Feed Assembly Turn Solenoid
actuates.
CAUTION:
Quickly verify component operation, then exit DG 84.
Extended operation of DG 84 may damage the Feed Assembly.
5. To Exit DG 84, repeatedly press [2] to cycle the LCD to
DG 00 Exit
Diagnostics
.
6. Press [1] to exit DG 84.