Specifications
Chapter 7: Using the Diagnostic Tool
7-14
DG 07 FUSER TEMP. SET
This Diagnostic code displays the fuser temperature setting for the printer. This is the value you
set in Configuration Mode Code 9 FUSER TEMP SET. The LCD displays a two digit hexadecimal
temperature code.
To run DG 07:
1. Enter Diagnostics Mode. The LCD displays a
Print Counter/Selecting DG
30
message. The printer is in Diagnostics mode.
2. Repeatedly press [2] until the LCD displays
DG 07
.
3. Press [1] to start the test.
The LCD displays a two digit temperature code. Use the following table
to determine the temperature setting.
Temperature Code
Displayed in LCD for 12
PPM
Configuration Mode
Code 9 Temperature
Setting
Temperature Code
Displayed in LCD for
12 PPM
Configuration Mode
Code 9 Temperature
Setting
C6 0 9E 8
C1 1 99 9
BC 2 94 A
B7 3 8F B
B2 4 8A C
AD 5 85 D
A8 6 80 E
A3 7 7B F
4. To Exit DG 07, repeatedly press [2] to cycle the LCD to
DG 00 Exit
Diagnostics
.
5. Press [1] to exit DG 07.