Specifications
Chapter 6: FRU Replacement and Fault Isolation Procedures
6-103
6.4.11 Residual image Continued
4. HEAT ROLL ASSEMBLY
If the spots occur at approximately 72-mm intervals, inspect the Heat Roll for
scratches, objects, or contamination.
Is the Heat Roll free of scratches and contamination?
Yes No
Go to Step 5 Replace the Heat Roll Assembly.
5. PRESSURE ROLL ASSEMBLY
If the spots occur at approximately 72-mm intervals, inspect the Pressure Roll for
scratches, objects, or contamination.
Is the Pressure Roll free of scratches and contamination?
Yes No
Return to Initial Analysis. Replace the Pressure Roll Assembly.