Specifications

Chapter 6: FRU Replacement and Fault Isolation Procedures
6-35
6.2.17 Inoperative key pad
NOTES:
1. Without the diagnostic tool, skip step 2
2. There is no corresponding control panel message for this
3. ESS (controller)
4. DO NOT USE THIS FIP except the initial analysis step 1 (and include the ESS (controller)
and the interconnect PWB) Also check for power and functionality on P/J 50 (the controller to
interconnect PWB to control panel also known as the console) and on P/J 51 (the controller
to interconnect PWB to LVPS) Note: P/J 20 is unused (for Diagnostic tool, only)
1. INITIAL ANALYSIS
Inspect the following components. Are they compatible with your printer version, correctly
installed, not damaged, deformed, or contaminated?
MCU PWB Controller (ESS)
LVPS Assembly Interconnect PWB
Console Assembly
Inspect the printer paper path. It is clear of foreign matter such as staples, paper clips, and paper
scraps?
Yes No
Go to Step 2 Replace the relevant components.
2. LVPS ANALYSIS
Disconnect P/J111 from the HVPS. Perform this test within 30 seconds after switching power on.
After 30 seconds, the LVPS shuts down with a no-load condition.
Switch ON Main Power.
Is there +5VDC between P/J 20–10 and P/J 11–2 on the MCU PWB?
Yes No
Go to Step 3 Go to 3.1 LVPS Assembly (+5VDC) Failure.