6.2.7 Paper Jam between Feeder and Reg. Sensor: Fault
code E2 continued
22. Is something causing the Registration Actuator to bind or stick?
Yes No
Remove whatever is interfering with the actuator. Go to Step 24.
23. REGISTRATION ACTUATOR ANALYSIS
Does the Registration Actuator expose the Registration Sensor window when a sheet of paper
strikes the actuator and does the Registration Actuator block the Registration Sensor window
when there is No paper striking the actuator?
Yes No
Go to Step 24 Replace the Inlet Chute Assembly.
24. REGISTRATION SENSOR ANALYSIS
Use Diagnostic Tool test DG02 to check the Registration Sensor. Does the Registration Sensor
function correctly and increment the DG02 number each time you actuate it?
Yes No
Replace the MCU PWB. Go to Section 6.3.8
Registration Sensor Assembly Failure.